ECU - 500
- Cooling power:500W
- Voltage:Three-phase AC 220/380V
- Installation method:
- Dimensions:W350*L400*H625mm
- Weight:40kg
Specifications Installing the dimensional
Model | ECU-500 | ||||||||||
Cooling mode | Air-Cooled type | ||||||||||
Performance | Cooling capacity [W] | 500 | |||||||||
Use Area temperature [℃] | 5~45 | ||||||||||
Oil temperature | Regulating range [℃] | 15~50 | |||||||||
Temperature difference [℃] | ±9 | ||||||||||
Oil viscosity [mm2/s] | 1.4~200 (ISO GV2~10) | ||||||||||
Usable Oil | Lubricant, hydraulic oil of mineral oil(Not usable for hydraulic oil of ester phosphate, water, water-soluble liquid, drugs, food products, fuel, cutting liquid, grinding liquid, etc.) | ||||||||||
Electrical characteristics | Power Supply [V] | 3AC 220/380V 50Hz | |||||||||
Rated power [W] | 600 | ||||||||||
Rated current [A] | 2 | ||||||||||
Components | Radiator | Finned tube type | |||||||||
Evaporator | Finned tube type | ||||||||||
Compressor | Rotary type | ||||||||||
Oil temperature sensor | Thermistor | ||||||||||
Control accuracy [℃] | ±0.5~1 | ||||||||||
Oil pump | Oil pump flow rate [L/min] | 3 | |||||||||
Opening pressure [Mpa] | 0.4 | ||||||||||
Piping interface | Oil inlet [Rp] | Rp1/2 | |||||||||
Oil outlet [Rp] | Rp1/2 | ||||||||||
Noise [dB] | ≤62 | ||||||||||
Protection [IP] | IP44 | ||||||||||
Oil tank [L] | 12 | ||||||||||
External dimensions(W*L*H) [mm] | 350x400x625 | ||||||||||
Weight [kg] | 40 |
Notes: 1. The cooling capacity represents the value at the standard point(inlet oil temperature:35℃,room temperature:35℃,oil for use:ISO VG32).
2. Be sure to use a commercial power supply for the power source.The use of an inverter power supply may cause burn damage to the unit.
3. 3.The yellow line on the tank oil level gauge shows the highest oil level and the red line the lowest oil level.